- Part Status :
- Operating Temperature :
- Size / Dimension :
-
- Rectangular - 118mm L x 117mm H (85mm Dia) (2)
- Rectangular - 143mm L x 137mm H (97mm Dia) (1)
- Rectangular - 144mm L x 137mm H (97mm Dia) (2)
- Rectangular - 159mm L x 168mm H (108mm Dia) (1)
- Rectangular - 162mm L x 165mm H (97mm Dia) (1)
- Rectangular - 174mm L x 190mm H (120mm Dia) (1)
- Rectangular - 204mm L x 213mm H (133mm Dia) (1)
- Rectangular - 226mm L x 247mm H (140mm Dia) (1)
- Rectangular - 226mm L x 261mm H (126mm Dia) (1)
- Rectangular - 261mm L x 281mm H (180mm Dia) (1)
- Rectangular - 314mm L x 345mm H (200mm Dia) (3)
- Rectangular - 342mm L x 424mm H (200mm Dia) (1)
- Rectangular - 380mm L x 473mm H (220mm Dia) (1)
- Rectangular - 404mm L x 448mm H (250mm Dia) (2)
- Rectangular - 417mm L x 486mm H (250mm Dia) (1)
- Rectangular/Rounded - 171mm L x 180mm H (1)
- Rectangular/Rounded - 178mm L x 193mm H (1)
- Rectangular/Rounded - 206mm L x 219mm H (146mm Dia) (1)
- Rectangular/Rounded - 220mm L x 216mm H (146mm Dia) (2)
- Rectangular/Rounded - 226.8mm L x 262mm H (158mm Dia) (1)
- Round - 140mm Dia (1)
- Weight :
-
- 1.7 lbs (771.1g) (1)
- 1.8 lbs (816.5g) (2)
- 2.7 lbs (1.2kg) (2)
- 22 lbs (10kg) (2)
- 28 lbs (12.7kg) (1)
- 3 lbs (1.4kg) (1)
- 3.5 lbs (1.6kg) (1)
- 30 lbs (13.6kg) (1)
- 32 lbs (14.5kg) (1)
- 33 lbs (15kg) (1)
- 4 lbs (1.8kg) (1)
- 4.5 lbs (2kg) (1)
- 40 lbs (18.1kg) (1)
- 44 lbs (20kg) (1)
- 6.6 lbs (3kg) (1)
- 7.5 lbs (3.4kg) (1)
- 7.7 lbs (3.5kg) (2)
- 8.2 lbs (3.7kg) (1)
- 8.5 lbs (3.9kg) (1)
- 9 lbs (4.1kg) (2)
- Air Flow :
-
- 1050.0 CFM (29.40m³/min) (1)
- 120.0 CFM (3.36m³/min) (2)
- 1250.0 CFM (35.00m³/min) (1)
- 1275.0 CFM (35.70m³/min) (1)
- 152.0 CFM (4.26m³/min) (1)
- 152.0 ~ 350.0 CFM (4.26 ~ 9.80m³/min) (1)
- 156.0 CFM (4.37m³/min) (1)
- 1600.0 CFM (44.80m³/min) (1)
- 179.5 CFM (5.03m³/min) (1)
- 2000.0 CFM (56.00m³/min) (1)
- 212.0 ~ 582.0 CFM (5.94 ~ 16.30m³/min) (1)
- 251.0 CFM (7.03m³/min) (1)
- 26.0 CFM (0.728m³/min) (1)
- 26.5 CFM (0.742m³/min) (1)
- 2800.0 CFM (78.40m³/min) (1)
- 318.0 CFM (8.90m³/min) (1)
- 350.0 CFM (9.80m³/min) (1)
- 370.0 CFM (10.36m³/min) (1)
- 420.0 CFM (11.76m³/min) (1)
- 450.0 CFM (12.60m³/min) (1)
- 55.9 CFM (1.57m³/min) (1)
- 700.0 CFM (19.60m³/min) (1)
- 820.0 CFM (22.96m³/min) (1)
- 91.0 CFM (2.55m³/min) (1)
- Applied Filters :
27 results
| Picture | Mfr Part # | QUANTITY | Inventory | MANUFACTURE | Description | Package | Series | Part Status | Voltage - Rated | Operating Temperature | Approvals | Ingress Protection | Termination | Size / Dimension | Features | Width | Weight | Power (Watts) | Air Flow | Static Pressure | Bearing Type | Fan Type | Noise | RPM | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| GLOBAL STOCKS | |||||||||||||||||||||||||
|
RFQ |
2,998
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 417X220MM 115VAC | RG25P | Obsolete | 115VAC | - | - | - | 2 Wire Leads | Rectangular - 417mm L x 486mm H (250mm Dia) | - | 220.0mm | 32 lbs (14.5kg) | 1100W | 1250.0 CFM (35.00m³/min) | - | Ball | Blower, Centrifugal | 96.0 dB(A) | - | |||
|
RFQ |
3,365
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 380X200MM 115VAC | RG22P | Obsolete | 115VAC | - | - | - | 2 Wire Leads | Rectangular - 380mm L x 473mm H (220mm Dia) | - | 200.0mm | 30 lbs (13.6kg) | 490W | 820.0 CFM (22.96m³/min) | - | Ball | Blower, Centrifugal | 86.0 dB(A) | - | |||
|
RFQ |
3,079
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 342X181MM 115VAC | RG20P | Obsolete | 115VAC | - | - | - | 2 Wire Leads | Rectangular - 342mm L x 424mm H (200mm Dia) | - | 181.0mm | 22 lbs (10kg) | 410W | 700.0 CFM (19.60m³/min) | - | Ball | Blower, Centrifugal | 83.0 dB(A) | - | |||
|
RFQ |
1,462
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 404X292MM 115VAC | RD25S | Obsolete | 115VAC | - | - | - | 2 Wire Leads | Rectangular - 404mm L x 448mm H (250mm Dia) | - | 292.0mm | 40 lbs (18.1kg) | 1150W | 2000.0 CFM (56.00m³/min) | - | Ball | Blower, Centrifugal | - | - | |||
|
RFQ |
3,911
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 404X378MM 115VAC | RD25S | Obsolete | 115VAC | - | - | - | 2 Wire Leads | Rectangular - 404mm L x 448mm H (250mm Dia) | - | 378.0mm | 44 lbs (20kg) | 1800W | 2800.0 CFM (78.40m³/min) | - | Ball | Blower, Centrifugal | - | - | |||
|
RFQ |
3,163
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 314X292MM 115VAC | RD20S | Obsolete | 115VAC | - | - | - | 2 Wire Leads | Rectangular - 314mm L x 345mm H (200mm Dia) | - | 292.0mm | 28 lbs (12.7kg) | 540W | 1275.0 CFM (35.70m³/min) | - | Ball | Blower, Centrifugal | - | - | |||
|
RFQ |
3,305
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 314X378MM 115VAC | RD20S | Obsolete | 115VAC | - | - | - | 2 Wire Leads | Rectangular - 314mm L x 345mm H (200mm Dia) | - | 378.0mm | 33 lbs (15kg) | 730W | 1600.0 CFM (44.80m³/min) | - | Ball | Blower, Centrifugal | - | - | |||
|
RFQ |
3,242
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 314X292MM 115VAC | RD20S | Obsolete | 115VAC | - | - | - | 2 Wire Leads | Rectangular - 314mm L x 345mm H (200mm Dia) | - | 292.0mm | 22 lbs (10kg) | 400W | 1050.0 CFM (29.40m³/min) | - | Ball | Blower, Centrifugal | - | - | |||
|
3,264
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 261X125MM 115VAC | G4E180 | Active | 115VAC | - | - | - | 2 Wire Leads | Rectangular - 261mm L x 281mm H (180mm Dia) | - | 125.0mm | 8.2 lbs (3.7kg) | 146W | 350.0 CFM (9.80m³/min) | - | Ball | Blower, Centrifugal | 65.0 dB(A) | - | ||||
|
731
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 226.8X130MM 115VAC | - | Active | 115VAC | -13 ~ 140°F (-25 ~ 60°C) | CSA, UL | IP44 | 4 Wire Leads | Rectangular/Rounded - 226.8mm L x 262mm H (158mm Dia) | PWM Control, Speed Sensor (Tach) | 130.0mm | 7.7 lbs (3.5kg) | 170W | - | - | Ball | Blower, Centrifugal | - | 2390 RPM | ||||
|
RFQ |
2,433
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 143X53MM 115VAC | G2S097 | Obsolete | 115VAC | - | - | - | 2 Wire Leads | Rectangular - 143mm L x 137mm H (97mm Dia) | - | 53.00mm | 1.8 lbs (816.5g) | 23.00W | 26.0 CFM (0.728m³/min) | - | Ball | Blower, Centrifugal | 37.0 dB(A) | - | |||
|
RFQ |
797
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 206X270MM 115VAC | D4E146 | Obsolete | 115VAC | - | CE, VDE | - | 2 Wire Leads | Rectangular/Rounded - 206mm L x 219mm H (146mm Dia) | - | 270.0mm | 7.7 lbs (3.5kg) | 128W | 450.0 CFM (12.60m³/min) | - | Ball | Blower, Centrifugal | 55.0 dB(A) | - | |||
|
RFQ |
1,631
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 220X178MM 115VAC | D2E146 | Obsolete | 115VAC | - | CE, VDE | - | 6 Position Rectangular Connector | Rectangular/Rounded - 220mm L x 216mm H (146mm Dia) | - | 178.0mm | - | 83.0W ~ 192W | 152.0 ~ 350.0 CFM (4.26 ~ 9.80m³/min) | - | - | Blower, Centrifugal | 33 ~ 52 dB(A) | - | |||
|
RFQ |
3,766
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 204X270MM 115VAC | D2E133 | Obsolete | 115VAC | - | - | - | 2 Wire Leads | Rectangular - 204mm L x 213mm H (133mm Dia) | - | 270.0mm | 9 lbs (4.1kg) | 195W | 420.0 CFM (11.76m³/min) | - | Ball | Blower, Centrifugal | 55.0 dB(A) | - | |||
|
RFQ |
1,125
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 144X140MM 115VAC | D2E097 | Obsolete | 115VAC | - | - | - | 2 Wire Leads | Rectangular - 144mm L x 137mm H (97mm Dia) | - | 140.0mm | 2.7 lbs (1.2kg) | 43.00W | 120.0 CFM (3.36m³/min) | - | Ball | Blower, Centrifugal | 47.0 dB(A) | - | |||
|
663
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 172X254MM 115VAC | D2E133 | Active | 115VAC | - | - | - | 2 Wire Leads | Rectangular/Rounded - 171mm L x 180mm H | - | 254.0mm | 9 lbs (4.1kg) | 180W | 370.0 CFM (10.36m³/min) | - | Ball | Blower, Centrifugal | 56.0 dB(A) | - | ||||
|
1,517
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 118X80MM 115VAC | G2E085 | Active | 115VAC | - | - | - | 2 Wire Leads | Rectangular - 118mm L x 117mm H (85mm Dia) | - | 80.00mm | 1.7 lbs (771.1g) | 28.00W | 55.9 CFM (1.57m³/min) | - | Ball | Blower, Centrifugal | 57.0 dB(A) | - | ||||
|
1,035
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 118X80MM 115VAC | G2E085 | Active | 115VAC | - | - | - | 2 Wire Leads | Rectangular - 118mm L x 117mm H (85mm Dia) | - | 80.00mm | 1.8 lbs (816.5g) | 22.00W | 26.5 CFM (0.742m³/min) | - | Ball | Blower, Centrifugal | 38.0 dB(A) | - | ||||
|
714
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 226X130MM 115VAC | G2E146 | Active | 115VAC | - | - | - | 3 Wire Leads | Rectangular - 226mm L x 261mm H (126mm Dia) | - | 130.0mm | 8.5 lbs (3.9kg) | 295W | 318.0 CFM (8.90m³/min) | - | Ball | Blower, Centrifugal | 69.0 dB(A) | - | ||||
|
609
In-stock
|
ebm-papst Inc. | BLOWER CENT 226X130MM 115VAC | G2E140 | Active | 115VAC | - | - | - | 2 Wire Leads | Round - 140mm Dia | - | 130.0mm | 7.5 lbs (3.4kg) | 115W | 251.0 CFM (7.03m³/min) | - | Ball | Blower, Centrifugal | 67.0 dB(A) | - | ||||
|
2,482
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 178X115MM 115VAC | - | Active | 115VAC | -13 ~ 140°F (-25 ~ 60°C) | GOST, UL | IP44 | - | Rectangular/Rounded - 178mm L x 193mm H | PWM Control, Speed Sensor (Tach) | 115.0mm | 4 lbs (1.8kg) | 46.00W | - | - | Ball | Blower, Centrifugal | - | 2320 RPM | ||||
|
788
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 144X140MM 115VAC | D2E097 | Active | 115VAC | - | CCC, CE, CSA, UL | - | 2 Wire Leads | Rectangular - 144mm L x 137mm H (97mm Dia) | - | 140.0mm | 2.7 lbs (1.2kg) | 43.00W | 120.0 CFM (3.36m³/min) | - | Ball | Blower, Centrifugal | 47.0 dB(A) | - | ||||
|
2,719
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 220X178MM 115VAC | D2E146 | Active | 115VAC | - | CE, VDE | - | 6 Position Rectangular Connector | Rectangular/Rounded - 220mm L x 216mm H (146mm Dia) | - | 178.0mm | - | 193W ~ 455W | 212.0 ~ 582.0 CFM (5.94 ~ 16.30m³/min) | - | - | Blower, Centrifugal | 50 ~ 63 dB(A) | - | ||||
|
1,189
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 226X130MM 115VAC | G2E140 | Active | 115VAC | - | - | - | 2 Wire Leads | Rectangular - 226mm L x 247mm H (140mm Dia) | - | 130.0mm | 6.6 lbs (3kg) | 130W | 179.5 CFM (5.03m³/min) | - | Ball | Blower, Centrifugal | 60.0 dB(A) | - | ||||
|
3,237
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 162X180MM 115VAC | D2E097 | Active | 115VAC | -40 ~ 176°F (-40 ~ 80°C) | CE, CSA, UL | IP22 | 2 Wire Leads | Rectangular - 162mm L x 165mm H (97mm Dia) | - | 180.0mm | 3.5 lbs (1.6kg) | 50.0W | 156.0 CFM (4.37m³/min) | - | Ball | Blower, Centrifugal | 45.0 dB(A) | 1100 RPM | ||||
|
2,841
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 159X115MM 115VAC | G2E108 | Active | 115VAC | - | - | - | 2 Wire Leads | Rectangular - 159mm L x 168mm H (108mm Dia) | - | 115.0mm | 3 lbs (1.4kg) | 35.00W | 91.0 CFM (2.55m³/min) | - | Ball | Blower, Centrifugal | 54.0 dB(A) | - | ||||
|
709
In-stock
|
ebm-papst Inc. | FAN BLWR CENT 174X115MM 115VAC | G2E120 | Active | 115VAC | - | - | - | 4 Wire Leads | Rectangular - 174mm L x 190mm H (120mm Dia) | - | 115.0mm | 4.5 lbs (2kg) | 105W | 152.0 CFM (4.26m³/min) | - | Ball | Blower, Centrifugal | 62.0 dB(A) | - | ||||